STEM-XE Combi

Product Description

・ Minimized operation, completing it all in one.

・ Real-time monitoring.

・ Dedicated inner chamber.

・ Easy to use even for beginners.

STEM-XE Combi 'How to isolate SVF'

Advantages

Stem Cell Isolation Made Possible with One Equipment
Minimize investment costs : No need for specialized personnel, dedicated facilities, or expensive equipment.
Simple Instuctions Even for Beginners
No need for separate experts: Even beginners can easily perform stem cell isolation with simple training.
Specialized Inner Chamber for Optimal Isolation Efficiency
Minimize investment costs: No need for specialized personnel, dedicated facilities, or expensive equipment.
Real-Time Monitoring of the Isolation Process
Through the front monitor, you can observe the stem cell isolation process in real-time.

Dedicated Inner Chamber

Dedicated Inner Chamber
1Optimized for Efficient Extraction.
2From Fat Input to SVF Extraction. All Operations Take Place Within a Single Chamber
3When Used as an Inner Chamber for IV, IV Injection Is Possible After Simple Treatment.
4Extracts SVF Without Loss

What is SVF?

What is SVF
SVF, typically extracted from adipose tissue, is a mixture of various cells that includes stem cells and growth factors. It holds great potential for powerful effects in various fields such as tissue regeneration, disease treatment, aesthetices, and anti-aging.

Protocol - SVF Extraction

1protocol
Extract 50cc of fat with LIPOKITII
2protocol
Inject the extracted fat in Inner-Chamber.
3protocol
Inject enzyme.
4protocol
Proceed enzyme treatment in Stem-XE combi.
5protocol
Proceed centrifugation.
6protocol
Extract isolated fat with TP-101. At this time, the extracted fat + enzyme reaction solution* is kept on standby for second enzyme reaction.
7protocol
Inject washing solution in Inner-chamber.
8protocol
Proceed washing in forward and reverse directions (left) so that the contents mix welll.
9protocol
Proceed washing in forward and reverse directions (right).
10protocol
Remove the washing solution after centrifugation (repeat washing process steps 7 to 11 one more time).
11protocol
Extract the SVF gathered at both ends.
12protocol
Add back the 1st[fat + enzyme] reaction solution* extracted in step 6, and repeat from step 4 (second enzyme reaction).

Specification

Product Name
STEM-XE Combi
Dimensions
400 x 580 x 420 ㎜
Weight
37 kg(Approx.)
Voltage
AC220V/60Hz