MEDIKAN PRODUCTS

Bio Revolution through innovation
A PRODUCT OF MEDIKAN STEM-XE Combi

Minimal operation for everyone. Automatic stem cell isolation device

STEM-XE Combi

Product Description

・ Minimized operation, completing it all in one.

・ Real-time monitoring.

・ Dedicated inner chamber.

・ Easy to use even for beginners.

STEM-XE Combi 'How to isolate SVF'

Knee Joint Injection LIVE SURGERY

Advantages

Stem Cell Isolation Made Possible with One Equipment
Minimize investment costs : No need for specialized personnel, dedicated facilities, or expensive equipment.
Simple Instuctions Even for Beginners
No need for separate experts: Even beginners can easily perform stem cell isolation with simple training.
Specialized Inner Chamber for Optimal Isolation Efficiency
Minimize investment costs: No need for specialized personnel, dedicated facilities, or expensive equipment.
Real-Time Monitoring of the Isolation Process
Through the front monitor, you can observe the stem cell isolation process in real-time.

Dedicated Inner Chamber

Dedicated Inner Chamber
1Optimized for Efficient Extraction.
2From Fat Input to SVF Extraction. All Operations Take Place Within a Single Chamber
3When Used as an Inner Chamber for IV, IV Injection Is Possible After Simple Treatment.
4Extracts SVF Without Loss

What is SVF?

What is SVF
SVF, typically extracted from adipose tissue, is a mixture of various cells that includes stem cells and growth factors. It holds great potential for powerful effects in various fields such as tissue regeneration, disease treatment, aesthetices, and anti-aging.

Protocol - SVF Extraction

1protocol
Extract 50cc of fat with LIPOKITII
2protocol
Inject the extracted fat in Inner Chamber.
3protocol
Inject enzyme solution.
4protocol
Turn the switch to the left(Ⅰ) to start enzyme mix process for 40 minutes.
5protocol
After mix process reaction, centrifugation starts automatically.
6protocol
Remove the fat and enzyme mixture from the center and store it for reprocessing.
7protocol
Inject washing solution in Inner-chamber.
8protocol
Turn the switch to the right (Ⅱ) to start 1st washing. The mix process will last for 1 minute.
9protocol
After mix process reaction, centrifugation starts automatically.
10protocol
Remove the washing solution from the center. Then repeat the washing process from steps 7 to 10 once more.
11protocol
After completing the washing process twice, extract the SVF collected at both ends.
12protocol
Proceed with the reprocessing using the fat and enzyme mixure stored in step 6.
(Follow the same procedure from steps 4 to 11.)

Specification

Product Name
STEM-XE Combi
Dimensions
400 x 580 x 420 ㎜
Weight
37 kg(Approx.)
Voltage
AC220V/60Hz

MEDIKAN

MEDIKAN Co., LTD.
#502, 217, Heojun-ro, Gangseo-gu, Seoul, Republic of Korea
TEL : +82-2-2668-6070 FAX : +82-2-2668-6072 email : marketing@medikan.com